Troubleshooting False Resistant DST Results
Learning Objectivesmention reasons and troubleshooting
Troubleshooting False Resistant DST Results
The common reasons for getting false resistant DST results, along with their corrective actions, are given in the table below:
Reason |
Corrective action |
Culture .contaminated or mixed culture |
Ensure the purity of the culture before DST |
Organism inoculum too heavy |
|
Suspension not homogeneous or had clumps |
Ensure that the starting suspension is uniformly homogenized. |
Growth control dilution too light |
Ensure that proper dilutions are used for inoculating the growth control tube. |
Drug not reconstituted properly |
Ensure that the lyophilized drugs are reconstituted as per the manufacturer’s instructions. |
Drug not stored properly |
Ensure that the reconstituted drugs are stored as per the manufacturer’s recommendations. |
Drug not added to the tube |
Ensure that the exact volume ( 100 µl) of the drug is added to the tube. |
MGIT tube not mixed properly after the addition of the organism suspension |
Ensure that MGIT tubes are mixed properly before loading the AST carrier into the MGIT instrument. |
Organism could be borderline-resistant |
Check the Growth units and repeat DST if GU is >95 but <100. |
Resources
GLI Practical Guide to TB Laboratory Strengthening
Assessment
Question |
Answer 1 |
Answer 2 |
Answer 3 |
Answer 4 |
Correct answer |
Correct explanation |
Page id |
Part of Pre-test |
Part of Post-test |
During DST, what is the volume of drug which must be added to the MGIT tubes? |
100 µl |
1000 µl |
2.5 ml |
4.0 ml |
1 |
Ensure that the exact volume ( 100 µl) of the drug is added to the tube. |
|
YES |
YES |