Disposal of biohazardous waste is essential to prevent contamination and possible infection of those handling the infected specimens.
At the end of each day, Cartridge-based Nucleic Acid Amplification Test (CBNAAT) laboratories generate contaminated material such as:
- Used sputum containers
- Used cartridges
- Transfer pipettes.
All used materials should be considered contaminated.
All infectious samples should be sealed in a biohazard bag and disposed off according to Biohazard Waste Disposal Guidelines under the National Pollution Control Guidelines, 2019.
- Contaminated materials should be picked up with a gloved hand and placed in a closed lid container of 5% phenol solution or a biohazard bag.
- At the end of the day, the phenol should be drained, and the materials/ bags should be autoclaved at 121°C at 15 psi pressure for 20 minutes.
- Once done, the materials should be cooled and sent to the common waste treatment facility for mutilation/ shredding or disposal.
It is a good practice to display the Standard Operating Procedures (SOPs) for the disposal of each item in the CBNAAT laboratory.