Samples collected for TrueNAT tests are tested immediately (if collected at TrueNAT facility) or transported on the same day to nearest linked TrueNAT facility.
- Collected samples are stored in the fridge (2°C to 8°C) with biosafety precautions during delay in testing/ transportation.
- Samples are transported to TrueNAT facility in a cool box (2°C to 8°C) with ice packs.
- At the TrueNAT laboratory:
- Processed sputum can be stored in lysis buffer for up to 1 week at 30°C or 3 days at 40°C.
- Processed non-sputum specimen can be stored in lysis buffer for 3 days at up to 40°C and 1 week at 30°C.
- The District TB Officer (DTO) needs to ensure stock of material used for specimen collection, storage and transportation at the collection center and TrueNAT facility.