Mercury is a harmful metal, and accidental spillage of mercury needs to be handled with care.

  • Use of mercury thermometer should be avoided in the laboratory. 
  • A spill kit for mercury must be available if metallic mercury is present in the lab. The directions provided in the kit should be followed
  • Spilled metallic mercury forms little spheres that roll into corners and cracks on the floor. If not completely cleaned up, mercury vapor will continue to be released into the air
  • DO NOT use mercury thermometers in ovens. If the thermometer breaks, the heat will lead to dangerous concentrations of mercury in the air.
  • Exercise additional caution, when placing or storing mercury thermometers to reduce the risk of breakage
  • The Standard Operating Procedures (SOP) for Mercury Spill management should be displayed in TB laboratories

Handling Mercury Spill

Items needed: 

  • Apron
  • Gloves
  • Two cards/X-ray films
  • Masks
  • Powdered Sulphur (optional)

Cleaning the Spill

  • Collect the mercury, using an index card or X-ray film, to form a pile or globule
  • Mercury-absorbing powders, such as sulphur, can be used to amalgamate mercury
  • Mercury waste and materials used in spill clean-up must be promptly placed in a sealed bottle
  • Store metallic mercury in tightly closed, sturdy containers
  • After all visible mercury has been collected, the area should be washed with a detergent solution, rinsed, and allowed to dry before use. This treatment should remove most remaining mercury residue
  • Under no circumstances should mercury be swept with a broom or vacuumed with an ordinary vacuum cleaner. These procedures will disperse mercury more quickly into the air and spread the contamination

 